What is a BOP control line fireproof and the PSI hose fire fighter working pressure rated

 

PME stainless steel armored hoses are flame resistance for hydraulic application. The BOP control line provide the flexible connection for blowout preventer system during the well control operation.

 

All PME fire fighter BOP hose assemblies are designed and tested as API 16D standards, American Petroleum Industry with stand the fire, high temperature and high pressure.

 

Fire proof BOP control hose assemblies are over ferruled with stainless steel armor as fireshield protection. The hoses convey hydraulic power constantly to the surface BOP control unit.

 

PME-16D-1IN-UN-15SS and PME-16D-1IN-UN-25SS features pressure rating 5000 Psi, 35 MPa with inside diameter 1". The hose connections crimped with thread by quickly installing hammer union ends.

 

Max. WP 3000 Psi PME produce are also available for customer's API 16D control systems for drilling well control equipment application. .

 

Hose Fire Fighter, BOP Control Line

Size: 1"

Working Pressure: 5000 Psi

Union Ends: 1" FIG602 MxF

Length: 15 Feet, 25 Feet

SS Armored: Yes

 

PME Sales Team

Tel: +86 21 5837 2350

Cell/WhatsApp: +86 138 1899 0736

Email: contact@pmeindustrial.com

Site: www.pmeindustrial.com












2019年10月14日星期一

Technical Question: When drilling rig contractors should change the BOP control hose for drilling rigs?

Recently we receive an technical question about fireproof BOP control hoses maintenance from drilling contractor for land rigs and offshore when they are doing during routine inspections of blowout preventer hose lines

BOP control hoses are designed and manufactured as API 16D. Oilfield service contractors need to think about some technical questions like:
How often should test pressure of BOP hoses?
What is the pressure rating should be tested at? 
When to change the BOP control lines out?



API 16D BOP fire safe control hoses are to used for hydraulic pressure for BOP Blowout Prevention system during drilling rigs operation. Pressure testing of BOP hoses AA armored should be done every time before they are operated. Rating working pressure is 35 MPa and 70 MPa. 

As BOP hoses are important parts of BOP control system, it should be changed out every 3 years for good working condition. If the outside layer appearance of hose has been damaged, you should change BOP hoses immediately, considering its high pressure usage at safety. 

Whatsapp: +8613818990736

For more questions, please contact with PME Technical Department. Our engineers will answer you quickly and professionally. 

Cell: +86 138 1899 0736
Tel: +86 21 5837 2350
Shanghai PME Industrial Co., Ltd

2019年8月15日星期四

What about the specification of BOP Hydraulic Control Lines API 16D Hoses?

Main Technical Specification and Drawings of BOP Fire safe Hoses Line.
1 pcs x 30' ft stainless steel armor covered PME Industrial BOP control hose 5000 PSI WP 7500 PSI Test Pressure 
1 pcs x 20' ft stainless steel SS armored PME Industrial  Blowout Preventer Control Hoses 5,000 PSI WP, 7,500 PSI Test
5k BOP control hosePME Industrial lines rubber hoses QTY 4 pcs oil well equipments
2 pcs PME Industrial  Annular BOP Hoses 71 mm, ID Armor: 85 mm, Size OD Armor: 89 mm
1-1/2" ID 60' ft BOP Hoses Assembly, PME Industrial , 5000 Psi working pressure, coupled with 1-1/2 stainless steel male NPT Each End, Stainless. 